Grant Temperature & Pressure V Alve Up To 300 Lt Models Gcs0

Code:GCS09

SKU:GCS09

£35.94 inc. VAT

Quantity
You must specify a quantity of at least 1
  • Out of stock - available in 3-5 days

Overview

7 bar 90 C " M parallel x 15mm compression Probe length: 97mm

Grant Temperature & Pressure Relief Valve – GCS09

Part Number: GCS09
For Unvented Cylinders up to 300 Litres
Type: Safety TPRV (Temperature & Pressure Relief Valve)

Ensure optimal safety in your unvented hot water system with the Grant GCS09 Temperature & Pressure Relief Valve, specifically designed for use with Grant cylinders up to 300 litres capacity. This essential component safeguards against excessive temperature or pressure build-up, automatically discharging water if safety thresholds are breached.

Fully compliant with G3 Building Regulations, the GCS09 TPRV combines pressure relief and thermal protection in one compact, robust valve – ideal for professional installers and competent DIY users maintaining or upgrading a Grant unvented cylinder.

 

Key Features

  • Genuine Grant spare part – factory-fitted specification for up to 300L models

  • Dual action: temperature and pressure relief for added safety

  • Automatically opens at 7 bar pressure or 90–95°C temperature

  • Essential for compliance with Building Regulation G3

  • Built-in probe and discharge connection for direct fit

  • Heavy-duty brass body for long-lasting reliability

  • Ideal for routine servicing, repairs, or safety upgrades

 

Compatible With

  • Grant unvented hot water cylinders with capacities up to 300 litres, including:

    • Grant DuoWave

    • Grant Wave

    • Other Grant models using a standard 7 bar / 90–95°C TPR valve

 If you're unsure about compatibility, our technical support team can help confirm the correct part for your setup.

 

When to Replace

  • Signs of leakage or dripping from the discharge pipe

  • Annual servicing or safety checks (as required under G3 regs)

  • Corrosion, limescale, or damage to the valve body or probe

  • Replacement of a faulty or seized TPR valve

  • System upgrades or compliance retrofits on older cylinders

 

Technical Specifications

  • Part Number: GCS09

  • Discharge Pressure: 7 bar

  • Discharge Temperature: 90–95°C

  • Material: Brass body with integrated sensing probe

  • Connection: 15mm compression inlet / standard discharge outlet

  • Application: Domestic unvented cylinder safety device

  • Certifications: Complies with G3 Building Regulations

You may also be interested in...

  • Information

    Grant Temperature & Pressure Relief Valve – GCS09

    Part Number: GCS09
    For Unvented Cylinders up to 300 Litres
    Type: Safety TPRV (Temperature & Pressure Relief Valve)

    Ensure optimal safety in your unvented hot water system with the Grant GCS09 Temperature & Pressure Relief Valve, specifically designed for use with Grant cylinders up to 300 litres capacity. This essential component safeguards against excessive temperature or pressure build-up, automatically discharging water if safety thresholds are breached.

    Fully compliant with G3 Building Regulations, the GCS09 TPRV combines pressure relief and thermal protection in one compact, robust valve – ideal for professional installers and competent DIY users maintaining or upgrading a Grant unvented cylinder.

     

    Key Features

    • Genuine Grant spare part – factory-fitted specification for up to 300L models

    • Dual action: temperature and pressure relief for added safety

    • Automatically opens at 7 bar pressure or 90–95°C temperature

    • Essential for compliance with Building Regulation G3

    • Built-in probe and discharge connection for direct fit

    • Heavy-duty brass body for long-lasting reliability

    • Ideal for routine servicing, repairs, or safety upgrades

     

    Compatible With

    • Grant unvented hot water cylinders with capacities up to 300 litres, including:

      • Grant DuoWave

      • Grant Wave

      • Other Grant models using a standard 7 bar / 90–95°C TPR valve

     If you're unsure about compatibility, our technical support team can help confirm the correct part for your setup.

     

    When to Replace

    • Signs of leakage or dripping from the discharge pipe

    • Annual servicing or safety checks (as required under G3 regs)

    • Corrosion, limescale, or damage to the valve body or probe

    • Replacement of a faulty or seized TPR valve

    • System upgrades or compliance retrofits on older cylinders

     

    Technical Specifications

    • Part Number: GCS09

    • Discharge Pressure: 7 bar

    • Discharge Temperature: 90–95°C

    • Material: Brass body with integrated sensing probe

    • Connection: 15mm compression inlet / standard discharge outlet

    • Application: Domestic unvented cylinder safety device

    • Certifications: Complies with G3 Building Regulations