Vaillant 470Mm Flue Extension
The Vaillant 470mm Flue Extension is a genuine high-quality component designed for use with Vaillant’s standard horizontal and vertical concentric flue systems. It is used to extend the reach of the flue pipe when the boiler is positioned further away from an external wall or roof exit than the standard flue kit allows.
This extension utilizes the 60/100mm diameter standard, where the inner 60mm pipe carries the exhaust gases and the outer 100mm pipe brings in fresh air for combustion.
Key Features and Specifications
Length: 470mm (Effective length once installed).
Diameter: 60/100mm concentric.
Compatibility: Designed for use with Vaillant ecoTEC Pro, Plus, and Exclusive boiler ranges.
Material: High-grade white powder-coated metal outer with a temperature-resistant plastic inner.
Joint Type: Push-fit "click-clock" system with pre-installed rubber seals for a watertight and gastight connection.
Genuine Part: Ensures full compliance with Vaillant’s manufacturer warranty and building regulations.
Common Applications
Wall Thickness: Used when the boiler is installed on an exceptionally thick external wall where the standard 700mm-800mm flue kit falls short.
Side Exits: Extending the flue run horizontally along a wall to reach an external exit point.
Internal Routing: Navigating the flue through cupboards or ceiling voids to reach the outside of the property.
Installation Guidelines
Support: Any flue run exceeding 1 meter must be supported with Vaillant-approved flue brackets (standard practice is one bracket per meter).
Fall: Horizontal flue runs should maintain a slight fall back toward the boiler (usually 3° or 52mm per meter) to allow condensate to drain back into the boiler's trap.
Lubrication: Use a silicone-based grease on the rubber seals to ensure a smooth, secure push-fit connection without tearing the gaskets.
Maximum Length: Always refer to the specific boiler manual to ensure the total flue length (including elbows and extensions) does not exceed the maximum allowable distance for the fan's capacity.
Essential Companion Products
Flue Brackets: 100mm Flue Support Clips.
Elbows: Vaillant 90° or 45° Flue Elbows (60/100mm) for navigating corners.
Lubricant: Silicone Flue Grease.
Standard Kit: Vaillant Horizontal or Vertical Flue Terminal Kit.
Specialist Support and Local Collection
When it comes to gas safety, using genuine manufacturer flue parts is non-negotiable. We stock the full range of Vaillant flueing options including 470mm, 1000mm, and 2000mm extensions.
Visit our trade counter at 61 Fullers Road, E18 2QB for immediate collection. Our team can help you calculate the total length and components required based on your boiler's specific installation manual.
You may also be interested in...
-
Information
The Vaillant 470mm Flue Extension is a genuine high-quality component designed for use with Vaillant’s standard horizontal and vertical concentric flue systems. It is used to extend the reach of the flue pipe when the boiler is positioned further away from an external wall or roof exit than the standard flue kit allows.
This extension utilizes the 60/100mm diameter standard, where the inner 60mm pipe carries the exhaust gases and the outer 100mm pipe brings in fresh air for combustion.
Key Features and Specifications
Length: 470mm (Effective length once installed).
Diameter: 60/100mm concentric.
Compatibility: Designed for use with Vaillant ecoTEC Pro, Plus, and Exclusive boiler ranges.
Material: High-grade white powder-coated metal outer with a temperature-resistant plastic inner.
Joint Type: Push-fit "click-clock" system with pre-installed rubber seals for a watertight and gastight connection.
Genuine Part: Ensures full compliance with Vaillant’s manufacturer warranty and building regulations.
Common Applications
Wall Thickness: Used when the boiler is installed on an exceptionally thick external wall where the standard 700mm-800mm flue kit falls short.
Side Exits: Extending the flue run horizontally along a wall to reach an external exit point.
Internal Routing: Navigating the flue through cupboards or ceiling voids to reach the outside of the property.
Installation Guidelines
Support: Any flue run exceeding 1 meter must be supported with Vaillant-approved flue brackets (standard practice is one bracket per meter).
Fall: Horizontal flue runs should maintain a slight fall back toward the boiler (usually 3° or 52mm per meter) to allow condensate to drain back into the boiler's trap.
Lubrication: Use a silicone-based grease on the rubber seals to ensure a smooth, secure push-fit connection without tearing the gaskets.
Maximum Length: Always refer to the specific boiler manual to ensure the total flue length (including elbows and extensions) does not exceed the maximum allowable distance for the fan's capacity.
Essential Companion Products
Flue Brackets: 100mm Flue Support Clips.
Elbows: Vaillant 90° or 45° Flue Elbows (60/100mm) for navigating corners.
Lubricant: Silicone Flue Grease.
Standard Kit: Vaillant Horizontal or Vertical Flue Terminal Kit.
Specialist Support and Local Collection
When it comes to gas safety, using genuine manufacturer flue parts is non-negotiable. We stock the full range of Vaillant flueing options including 470mm, 1000mm, and 2000mm extensions.
Visit our trade counter at 61 Fullers Road, E18 2QB for immediate collection. Our team can help you calculate the total length and components required based on your boiler's specific installation manual.
Product Enquiry
Please provide your contact information below and we will get back to you as soon as possible.
Price match for Trade accounts
Click & Collect from Bridgwater or London
Next Working Day Delivery - UK wide distribution