Potterton Gold Isolation Relay - RL1

Code:BA1001

SKU:BA1001

£167.99 inc. VAT

Quantity
You must specify a quantity of at least 1
  • Available to order on request

Order withinhours andminutes for same day dispatch

Overview

Suitable for boilers Not suitable for switching the main power to the boilers

Potterton Gold RL1 Isolation Relay

The RL1 isolation relay is used when connecting 1 electric boiler on the same power supply as an electric shower.  Allows for the boiler to cut out when the electric shower is switched on.
 

  • Contact rating: 10 amps 250Vac
  • Coil consumption: 500mW
  • Coil operating voltage: 230Vac
  • Temperature range: -40°C to +70°C


The relay assemblies are mounted on a DIN rail contained in a plastic housing. They can be used for a variety of applications including controlling the boilers and operating pumps. To prevent overloading of the electrical supply where an electric boiler is installed together with an electric shower the RL1 assembly may be used to temporarily shut down the boiler when the shower is in use. When 2 or more boilers are used together the output supply must be isolated. For a 2-boiler system use the RL2 assembly for a 3-boiler system use the RL3 assembly.

These assemblies are quite suitable for boilers connected on a single-phase supply or for boilers connected to different phases of a 3-phase supply.
They are not suitable for switching the main power to the boilers.

  • Information

    Potterton Gold RL1 Isolation Relay

    The RL1 isolation relay is used when connecting 1 electric boiler on the same power supply as an electric shower.  Allows for the boiler to cut out when the electric shower is switched on.
     

    • Contact rating: 10 amps 250Vac
    • Coil consumption: 500mW
    • Coil operating voltage: 230Vac
    • Temperature range: -40°C to +70°C


    The relay assemblies are mounted on a DIN rail contained in a plastic housing. They can be used for a variety of applications including controlling the boilers and operating pumps. To prevent overloading of the electrical supply where an electric boiler is installed together with an electric shower the RL1 assembly may be used to temporarily shut down the boiler when the shower is in use. When 2 or more boilers are used together the output supply must be isolated. For a 2-boiler system use the RL2 assembly for a 3-boiler system use the RL3 assembly.

    These assemblies are quite suitable for boilers connected on a single-phase supply or for boilers connected to different phases of a 3-phase supply.
    They are not suitable for switching the main power to the boilers.