Heating Parts Specialist Online

0 items
£0.00
0 items Order Value £0.00 Checkout

exc. VAT

inc. VAT

Baffles

Grant Baffle Set Wbs03 Vortex Wh 12-21Kw 16/21

Code:226363

SKU:WBS03

£130.62 inc. VAT

Quantity
You must specify a quantity of at least 1
  • Out of stock - available in 7-10 days

Overview

WALLHUNG

Grant Baffle Set – WBS03

Genuine Baffle Set for Grant Vortex Wall Hung 12–21kW & 16/21kW Boilers

The Grant WBS03 Baffle Set is a genuine replacement flue baffle kit designed specifically for use with Grant Vortex Wall Hung 12–21kW and 16/21kW oil-fired condensing boilers. These baffles play a critical role in improving boiler efficiency by slowing down the flow of hot combustion gases through the heat exchanger. This allows for greater heat transfer into the central heating system, reducing fuel consumption and emissions.

Worn or missing baffles can lead to inefficient operation, excessive soot build-up, and higher fuel costs. Replacing them with the WBS03 set ensures your boiler continues to operate at optimal performance.

 

  Key Features & Benefits

  • Official Grant Part – WBS03
    Manufacturer-approved baffle set for precise fit and reliable operation in Grant Wall Hung boilers.

  • Enhances Boiler Efficiency
    Slows flue gas movement through the heat exchanger, maximizing heat transfer.

  • Reduces Fuel Consumption & Emissions
    Improved combustion efficiency means lower heating bills and a reduced carbon footprint.

  • Supports Cleaner Operation
    Minimises soot and carbon deposits in the combustion chamber and flueways.

  • Robust & Heat-Resistant Construction
    Built from materials designed to withstand high combustion temperatures for long service life.

  • Quick & Easy Installation
    Straightforward to fit during annual boiler servicing or routine maintenance.

 

 

Compatible Grant Boiler Models

The WBS03 Baffle Set is suitable for:

  • Grant Vortex Wall Hung 12–21kW (internal and external)

  • Grant Vortex Wall Hung 16/21kW

Not sure if this baffle set suits your boiler? Contact our expert team with your model or serial number, and we’ll confirm compatibility.

 

 

 When Should You Replace the Baffle Set?

Replace your boiler baffles if:

  • They show signs of warping, corrosion, or cracking

  • There is excessive soot or incomplete combustion

  • Your boiler is using more fuel than normal or suffering reduced heat output

  • You’re completing a routine service or heat exchanger clean

Replacing faulty baffles helps maintain the designed airflow and combustion chamber dynamics, critical for system efficiency and safety.

 

 

 Technical Specifications

  • Part Number: WBS03

  • Manufacturer: Grant UK

  • Component Type: Flue gas retarders / baffles

  • Material: High-temperature-resistant metal alloy

  • Installation: Preformed to slot into designated locations in the heat exchanger

  • Boiler Range: Grant Vortex Wall Hung models (12–21kW and 16/21kW)

  • Function: Improve heat retention and flue gas velocity control

  • Information

    Grant Baffle Set – WBS03

    Genuine Baffle Set for Grant Vortex Wall Hung 12–21kW & 16/21kW Boilers

    The Grant WBS03 Baffle Set is a genuine replacement flue baffle kit designed specifically for use with Grant Vortex Wall Hung 12–21kW and 16/21kW oil-fired condensing boilers. These baffles play a critical role in improving boiler efficiency by slowing down the flow of hot combustion gases through the heat exchanger. This allows for greater heat transfer into the central heating system, reducing fuel consumption and emissions.

    Worn or missing baffles can lead to inefficient operation, excessive soot build-up, and higher fuel costs. Replacing them with the WBS03 set ensures your boiler continues to operate at optimal performance.

     

      Key Features & Benefits

    • Official Grant Part – WBS03
      Manufacturer-approved baffle set for precise fit and reliable operation in Grant Wall Hung boilers.

    • Enhances Boiler Efficiency
      Slows flue gas movement through the heat exchanger, maximizing heat transfer.

    • Reduces Fuel Consumption & Emissions
      Improved combustion efficiency means lower heating bills and a reduced carbon footprint.

    • Supports Cleaner Operation
      Minimises soot and carbon deposits in the combustion chamber and flueways.

    • Robust & Heat-Resistant Construction
      Built from materials designed to withstand high combustion temperatures for long service life.

    • Quick & Easy Installation
      Straightforward to fit during annual boiler servicing or routine maintenance.

     

     

    Compatible Grant Boiler Models

    The WBS03 Baffle Set is suitable for:

    • Grant Vortex Wall Hung 12–21kW (internal and external)

    • Grant Vortex Wall Hung 16/21kW

    Not sure if this baffle set suits your boiler? Contact our expert team with your model or serial number, and we’ll confirm compatibility.

     

     

     When Should You Replace the Baffle Set?

    Replace your boiler baffles if:

    • They show signs of warping, corrosion, or cracking

    • There is excessive soot or incomplete combustion

    • Your boiler is using more fuel than normal or suffering reduced heat output

    • You’re completing a routine service or heat exchanger clean

    Replacing faulty baffles helps maintain the designed airflow and combustion chamber dynamics, critical for system efficiency and safety.

     

     

     Technical Specifications

    • Part Number: WBS03

    • Manufacturer: Grant UK

    • Component Type: Flue gas retarders / baffles

    • Material: High-temperature-resistant metal alloy

    • Installation: Preformed to slot into designated locations in the heat exchanger

    • Boiler Range: Grant Vortex Wall Hung models (12–21kW and 16/21kW)

    • Function: Improve heat retention and flue gas velocity control