Heating Parts Specialist Online

0 items
£0.00
0 items Order Value £0.00 Checkout

exc. VAT

inc. VAT

Pipe

Keyplumb Ufh 200M X 16Mm Pert-Al-Pert Coil

Code:11422

SKU:11422

£114.00 inc. VAT

Quantity
You must specify a quantity of at least 1
  • In Stock

Order withinhours andminutes for same day dispatch

Overview

Underfloor Heating 16mm Pipe 200 meters length

The Keyplumb 200m x 16mm PERT-AL-PERT Coil (Part Number: S-11422) is a high-performance multilayer composite pipe designed for larger underfloor heating (UFH) projects. This 200-meter length is double the standard coil size, allowing you to run multiple loops or a single very long loop (though industry standards recommend keeping individual loops under 100-110m to avoid pressure drops).

The PERT-AL-PERT construction features an internal aluminum core that provides a 100% oxygen barrier and, crucially, ensures the pipe holds its shape when bent—eliminating the "spring-back" common with standard plastic pipes.

Key Features and Specifications

Dimensions: 16mm Outside Diameter (OD) x 2.0mm Wall Thickness.

Length: 200-meter coil (Ideal for 2 standard loops of ~100m each).

Construction: 5-layer composite (PERT-Adhesive-Aluminum-Adhesive-PERT).

Performance: Rated for a sustained working temperature of 70°C and pressures up to 10 bar.

Certifications: WRAS approved (safe for potable water) and manufactured to ISO9001 standards.

Form-Stable: The aluminum core allows for easy hand-forming and tight bends (minimum radius ~80mm) without the pipe kinking or springing back.

Coverage Guide (Approximate)

A 200m coil provides significant coverage depending on your pipe spacing:

200mm Spacing (Standard): Covers approximately 40m².

150mm Spacing (High Heat Loss): Covers approximately 30m².

100mm Spacing (Maximum Output): Covers approximately 20m².

Note: Always allow extra for the "tails" running back to the manifold.

Installation Best Practices

Manifold Planning: For a 200m coil, it is best practice to cut it into two 100m loops. Running a single 200m loop is not recommended as it can lead to uneven heating and strain on the Grundfos UPM3 pump.

Calibration: You must use a 16mm Calibration Tool. Because of the aluminum layer, the pipe must be re-rounded and chamfered after cutting to protect the O-rings on your Eurocone connectors.

Decoiler Use: A 200m coil is heavy (approx. 20-22kg). Using a pipe decoiler is highly recommended to prevent twists and tangles during installation.

Essential Companion Products

Connectors: Keyplumb 16mm Eurocone Adaptors.

Fixings: 60mm UFH Clips .

Pump: Grundfos UPM3 Flex 25-70 130. 

Blending: 1" UFH Mixing Valve with Gauges.

Specialist Support and Local Collection

We stock 200m coils for immediate collection at our trade counter at 61 Fullers Road, E18 2QB. These coils are often preferred by installers for larger open-plan kitchen/diners to minimize waste.

 

You may also be interested in...

  • Information

    The Keyplumb 200m x 16mm PERT-AL-PERT Coil (Part Number: S-11422) is a high-performance multilayer composite pipe designed for larger underfloor heating (UFH) projects. This 200-meter length is double the standard coil size, allowing you to run multiple loops or a single very long loop (though industry standards recommend keeping individual loops under 100-110m to avoid pressure drops).

    The PERT-AL-PERT construction features an internal aluminum core that provides a 100% oxygen barrier and, crucially, ensures the pipe holds its shape when bent—eliminating the "spring-back" common with standard plastic pipes.

    Key Features and Specifications

    Dimensions: 16mm Outside Diameter (OD) x 2.0mm Wall Thickness.

    Length: 200-meter coil (Ideal for 2 standard loops of ~100m each).

    Construction: 5-layer composite (PERT-Adhesive-Aluminum-Adhesive-PERT).

    Performance: Rated for a sustained working temperature of 70°C and pressures up to 10 bar.

    Certifications: WRAS approved (safe for potable water) and manufactured to ISO9001 standards.

    Form-Stable: The aluminum core allows for easy hand-forming and tight bends (minimum radius ~80mm) without the pipe kinking or springing back.

    Coverage Guide (Approximate)

    A 200m coil provides significant coverage depending on your pipe spacing:

    200mm Spacing (Standard): Covers approximately 40m².

    150mm Spacing (High Heat Loss): Covers approximately 30m².

    100mm Spacing (Maximum Output): Covers approximately 20m².

    Note: Always allow extra for the "tails" running back to the manifold.

    Installation Best Practices

    Manifold Planning: For a 200m coil, it is best practice to cut it into two 100m loops. Running a single 200m loop is not recommended as it can lead to uneven heating and strain on the Grundfos UPM3 pump.

    Calibration: You must use a 16mm Calibration Tool. Because of the aluminum layer, the pipe must be re-rounded and chamfered after cutting to protect the O-rings on your Eurocone connectors.

    Decoiler Use: A 200m coil is heavy (approx. 20-22kg). Using a pipe decoiler is highly recommended to prevent twists and tangles during installation.

    Essential Companion Products

    Connectors: Keyplumb 16mm Eurocone Adaptors.

    Fixings: 60mm UFH Clips .

    Pump: Grundfos UPM3 Flex 25-70 130. 

    Blending: 1" UFH Mixing Valve with Gauges.

    Specialist Support and Local Collection

    We stock 200m coils for immediate collection at our trade counter at 61 Fullers Road, E18 2QB. These coils are often preferred by installers for larger open-plan kitchen/diners to minimize waste.